This page is intended to help users get their own bridge fragilities into MAEviz. The information you will find in this document is:

  • File Types and Format
  • Field Descriptions

File Types and Format

There are two acceptable formats, comma separated value (CSV) and Extensible Markup Language (XML). The simplest way to get fragilities into MAEviz is the CSV format which will internally be changed to XML. Both formats will be explained in their own section after the field descriptions.

Field Descriptions

Where there are a limited number of possible inputs, they will be specified in the Acceptable Values column in the table below or N/A for not applicable (e.g. author would be N/A). The informational column tells you if the attribute is for informational purposes or actually used internally by MAEviz. For example, the Code column is informational and simply tells the user if the fragility was intended as a retrofit and if so, what type. The fragility mapping is what will determine which fragility gets applied to which bridge. See the Fragility Mapping documentation for more about this topic.

Field Name

Field Description

Field Type

Acceptable Values

Informational

ID

Unique numeric identifier in the fragility dataset

Integer

N/A

No

Author

Identifies the person(s) who provided each fragility set.

String

N/A

Yes

StructureType

Structure Type this fragility curve is designed for

String

N/A

Yes

Description

A textual description providing information about the derivation of this fragility curve set

String

N/A

Yes

GroundMotions

Ground motion records used for time-history analyses when constructing fragilities

String

 

Yes

Code

Design code for the fragility set

String

low - no retrofit, seat extender, steel jacket, Restrainer cables, Shear Key, Elastomeric Bearing

Yes

DamageType

The type of damage type this fragility represents

String

Structural

Yes

DemandType

The demand type required by the fragility, can include the period if applicable (e.g. 0.2 Sa )

String

PGA, PGV, PGD, Sa, Sd, Sv

No

DemandUnits

The units of the demand type

String

g

No

LimitStates

The limit states of the fragility curves, MAEviz expects 4 limit states. This tells MAEviz how many fragility curves to expect.

String

Slight: Moderate: Extensive: Complete

No

EquationType

The fragility equation type

Integer

1 - Lognormal distribution, 2 - Normal Distribution

No

Parameters

The number of fragility parameters present (should be 2 parameters per fragility, median and beta)

Integer

N/A

No