Advanced Computational Health Enclave

Definition:

The Advanced Computational Health Enclave (ACHE) is a physically and virtually segmented zone for processing and storing electronic personal health information (ePHI). 

Types of Systems:

ACHE is the only approved space for storing and processing ePHI, and both physical and electronic access is restricted to those staff who need it. These systems often have high-availability needs, and hence this zone has a separate UPS backup system. Like the HPDC zone, these systems are first built in a firewalled subzone until fully vetted by the security team, which is responsible for regular auditing against the additional security requirements below.

ACHE is a separately monitored zone that inherits all of the requirements of systems in the HPDC, plus additional host configuration requirements.

Installation Requirements:

Informational Requirements:

  • The authorized set of administrators must all be in the NCSA Health Care Component (NHCC), and this group's access must be automated by a process approved by the NCSA HIPAA liaison.
    • The security operations team is part of this group and must be able to access systems 24/7 in an emergency.
  • It is assumed that ePHI, which is high risk data, is on these systems. These are not dual-use systems but are only for work related to health and medicine. The NCSA HIPAA liaison must be informed of any new type of data on these systems, especially when personally identifying information is recorded.
  • Accepted (by the NCSA HIPAA liaison) vulnerability and patch management procedures must be in place.
  • Accepted (by the NCSA HIPAA liaison) change control procedures must be implemented and documented.
  • Local and privileged account passwords are managed with the NCSA-provided, two-factor password management solution.

Host Configuration Requirements:

  • Disable any unnecessary services and accounts, and enforce with host-based firewalls where possible.
  • Enable host-based brute-force mitigations utilizing the security team's host-based IDS if possible.
  • Forward system logs to the security team's log collector.
  • Two-factor authentication is required for remote access. Single-sign-on is limited to 10 million seconds, the lifetime of a short-lived grid certificate
  • User are automatically logged-off for inactivity, and SSH sessions do not last more than 24 hours.
  • Require two-factor bastions, jump-hosts or VPNs for access to administrative interfaces.
  • Routing, traffic forwarding, bridging subnets and other forms of internetwork traffic proxy is prohibited without expressed permission from Security & Networking.
  • ePHI is encrypted in transit and rest.
  • Shared, writable file-systems must be securely wiped between jobs from different users or organizations.
  • Data transfer endpoints must be whitelisted and scoped to the customer's networks.
  • Motd and other welcome screens for users or administrators must remind them of the systems's sensitivity, the requirement for laptop encryption, that the system is only for authorized staff and clients, and the University's policies for HIPAA protected data.

Network Monitoring:

All external links in and out of this zone are monitored by the NIDS. New hosts that appear on this network but have not been vetted may be automatically or manually blocked at the border gateway until investigated and vetted. Network traffic entirely within this zone is unmonitored by the NIDS, but network flows are collected.

Anchor
InstallationSubzone
InstallationSubzone
Installation Subzone

While new systems are being built and configured in this zone and before they are fully vetted by security, they are firewalled in a subzone.

Host Configuration Requirements:

These systems must:

  • Use secure, non-default passwords.
  • Be protected by a stateful, network firewall that only accepts connections for approved, secure remote access services.

Research & Internal Services Zone

Definition:

This zone includes all Raised Access Floor (RAF) space in the NCSA building, as well as a logical zone in the NPCF data center. 

Types of Systems:

This zone is for servers supporting R&D projects and internal services at NCSA. The IIB determines which systems are placed in this zone based on space, power, cooling, security and networking considerations together with ADS and Security. Systems in this zone do not have the same baseline service level guarantees as those in the HPDC zone, including security services provided.

Servers, whether supporting internal NCSA services or NCSA projects and their customers, are important, and their compromise can have a significant effect NCSA productivity and reputation. Whether or not they are even considered production servers, the impact can be significant if the data on the systems is exposed due to privacy considerations, regulatory & legal requirements, or confidentiality agreements. Therefore, certain accountability is still required of all these systems.

Informational Requirements:

Systems or their administrators must:

...

It is important that changes in the information initially provided to the security team are kept up-to-date, and system owners will need to update this annually. Changes to include high risk or confidential data need to be updated as soon as possible by contacting Security.

Host Configuration Requirements:

Systems or their administrators must:

...

NCSA Office & Wireless Zone

Definition:

This zone includes all of the office and wireless networks that assign NCSA IP addresses. This includes offices in the NCSA building, NPCF and at least one wireless network, but does not include most RAF space.

Types of Systems:

This zone supports a variety of systems including desktops, laptops, portable devices and research systems. This zone is the most flexible and has the fewest security controls. While firewalled subnets are encouraged by default, the policies that apply broadly to every host are campus and NCSA employee security policies and a requirement to register hosts using an NCSA ID before accessing the network.

...

  • System owners must follow all campus and NCSA employee policies regarding software updating, virus scanning, data security, incident reporting, etc.
  • New systems must be registered with an NCSA ID to receive an IP address and if different from the NCSA ID, give a point-of-contact for Security.
    • The default network type is firewalled, though users can opt-out
    • Network registration is only for NCSA staff and should not be done for guests. Guest accounts and temporary registrations are available for these use cases.
    • Reregistration is required annually.
  • Business Office systems are administered and maintained by ITS, and the corresponding workstations and laptops are on a firewalled network.

Host Configuration Requirements:

  • Systems do not bridge or create new NCSA subnets (wired or wireless) without approval from Networking & Security.

...

Systems connected to the NCSA VPN are monitored unencrypted on the internal side of the VPN with the NIDS. Authentication to the VPN requires the use of valid and authorized NCSA credentials.

...

Physical Security Zone

Definition:

This is an isolated zone only for the NPCF physical security systems.

Types of Systems:

All NPCF physical security systems, and only those systems, are part of this zone.  This includes the camera DVRs, badge readers, iris scanners, ACMS workstations (for badging, control and enrollment), and the ACMS database server.

Host Configuration Requirements:

  • Devices on this network can neither connect to the other networks or be connected to except for a single ACMS workstation that must connect with iCard systems elsewhere on campus.
    • This ACMS workstation can only be connected to via RDP from a single remote workstation run by Facilities & Services for troubleshooting and support.
  • All other remote connections, even if temporary for support, must be approved by the Security Office. 

...

Isolated Zones

Definition:

Sometimes there is a need for a special subnet that is treated no differently than an external network and does not route internally with NCSA systems. This could be because the systems on the subnet would not meet the requirements of this policy (e.g., they bring their own unmonitored WAN links or cannot be hardened sufficiently), it is actually an external network extruding into our physical infrastructure, or that external requirements or regulations require extra isolation.

...